Buyer information, not installation instructions. Requirements depend on the adopted local code and exact product. Electrical work and site diagnosis should be performed by qualified professionals.
GFCI protection addresses electric shock from ground faults. AFCI protection addresses fire hazards caused by dangerous electrical arcing. A project can need both functions; the device documentation should identify each one. [Source]
| Protection | Hazard addressed | What to specify |
|---|---|---|
| GFCI | Ground-fault current that can cause electric shock | Ground-fault protection for the required circuit or location |
| AFCI | Hazardous electrical arcing that can cause a fire | Arc-fault protection for the required circuit |
| Both | Both of the hazards above | Documentation identifying both protection functions |
Where GF15 and GF20 fit
FAHINT GF15 and GF20 are self-test GFCI receptacles rated 15A and 20A respectively. They belong on a GFCI shortlist. Their GFCI designation does not establish AFCI protection.
A GFCI monitors the current path and interrupts power when it detects a ground fault. Its purpose differs from the overload protection of a conventional circuit breaker. [Source]
Put both requirements in the brief
Have the project’s electrical professional identify the protection required under the locally adopted code. For a circuit needing both functions, keep both in the specification through product selection and approval. The circuit arrangement and panel compatibility also need professional review.
- Required protection: GFCI, AFCI or both.
- Voltage, current rating and receptacle configuration.
- Installation environment and any TR or WR requirement.
- Exact model, listing documents and supplied instructions.
For a FAHINT GFCI order, include the full model and required features when requesting documents. This keeps a change of current rating or face style from becoming an unintended change of protection.
Which device sits on which circuit
In a typical North American installation the two functions live in different places. Ground-fault protection is usually a receptacle at the point of use — GF15 or GF20 here — while arc-fault protection is usually a breaker at the panel. That arrangement is common because it is convenient, not because one device implies the other.
Dual-function breakers exist and are specified in some jurisdictions, and combination devices that carry both functions in one package are also on the market. Where a drawing calls for both protections at the point of use, the device has to be marked for both functions; a GFCI-only receptacle cannot supply arc-fault protection, and which product closes that gap depends on the specification rather than on a single default answer.
Purchase orders lose this distinction more often than drawings do. A line reading "GFCI outlet, 20A, both protections" is a line that has to be queried before it can be quoted, because the second half belongs to a different product family.
The clean way to buy protection through a receptacle supplier is to state the function the device must perform and let the installer decide where it belongs. Where the answer is "GFCI at the point of use", the model list is short and the specification is unambiguous.